Morgan Lens Instructions For Use:

Below are the instructions for using the Morgan Lens for continuous medication or lavage to the cornea and conjunctiva.

You can download the printer-friendly PDF version of the Morgan Lens Instructions For Use by clicking here

Morgan Lens Recommended Uses:

 

 

Solution: Step 1: INSERTION. Instill topical ocular anesthetic, if available.


Mode: Morgan Lens Delivery Set or I.V. set-up
Frequency: Once. Wait 5 to 10 minutes and check pH. Repeat as necessary.


Alkali Burns Solution: Lactated Ringer’s Solution*
Rate:
2000 ml rapid/free flow. Reassess and continue at 50 ml/hour or 15 drops/minute


Mode: Morgan Lens Delivery Set or I.V. set-up
Frequency:
Continuous until pH of cul-de-sac returns (and remains) neutral.


Non-embedded foreign bodies Solution: Lactated Ringer’s Solution*
Rate:
500 ml rapid/free flow. Reassess
and continue at slower rate.


Mode: Morgan Lens Delivery Set or I.V. set-up
Frequency:
Once. Repeat as necessary.


Foreign body sensation with no visible foreign body Solution: 20 cc sterile solution
Rate: Slowly without force.


Mode: 20 cc syringe
Frequency:
Once. Repeat once if necessary.



Routine pre-operative
Solution: 10 cc of preferred ocular antiseptic
Rate:
Slowly without force.


Mode: 10 cc syringe
Frequency: Once.


Eyelid surgery Solution: Lactated Ringer’s Solution*
Rate: 4 drops/minute.


Mode: Morgan Lens Delivery Set or I.V. set-up
Frequency: During entire procedure.


Severe infection Solution: Lactated Ringer’s Solution* with
suitable antibiotic and steroid**
Rate:
Slowly without force.
Mode: Morgan Lens Delivery Set or I.V. set-up
Frequency: Continuous for 70 hours, then 10-hour intervals until marked improvement.


*Recommendation to use lactated Ringer’s based on pH:
Tears approximately 7.1
Normal Saline 4.5 to 7.0
lactated Ringer’s 6.0 to 7.5

**Use only when indicated.